Settings for the Radiator Control

Home Network / Smart Home / Edit Radiator Control

Radiator controls – FRITZ!DECT 301/300 or Comet DECT – can be connected with the FRITZ!Box via DECT radio and controlled in the user interface. Up to 12 radiator controls can be set up in the FRITZ!Box.

Settings

Overview

The following settings are available:

SettingDescription
Keylock

When the keys are locked, manual operation of the radiator control is blocked. This applies to the following possible operations:

  • Buttons and setting wheel on the radiator control (pressing a button only switches the display on)
  • FRITZ!Box user interface
  • MyFRITZ!App
  • FRITZ!Fon
Schedule For each individual weekday you can specify at what times a previously specified temperature is to be maintained. Outside these times a defined setback temperature is maintained.
Vacation switching (party switching) Define up to 4 periods during which the schedule is disabled and a constant temperature is maintained.
Heating off Define a period during which the heating is off. The heating valve remains closed during this time and the radiator control is set to an expanded power saving mode to save battery power.
Open window detection Closes the heating valve automatically when the room temperature radically drops. The valve remains closed for a previously specified time (1—120 minutes). The defined period also applies for enabling the open window detection with a button on the radiator control.
Temperature offset Correction value if the temperature on the radiator control deviates from the temperature in the rest of the room.
Push service Sends you a notification by e-mail when certain events occur.